1 System Basic Configuration

1.2 General Connection Diagram

1.2.1 General Connection Diagram [M800W]

Windows-based display (15-type)
Dotted lines indicate the sections prepared by the machine tool builder.
<> Angle brackets indicates attached cable of unit.
L1 L2 L3
No-fuse breaker
(NFB)
ON
OFF
MC
MC
MC
24VDC stabilized
power supply
DCOUT
ACIN
FG
CP
(Note 1)
Drive units
Handy terminal
Analog output : 2 points
G430
(Note 1) For information on how to connect the drive unit, refer to the drive unit's manual.
(Note 2) When using a keyboard unit, install the operation panel I/O unit on the back of the keyboard unit.
Note
(1) For the connection of MITSUBISHI CNC machine operation panel, refer to "M800W/M80W Series Connection and Set-
up Manual".
IB-1501273-F
Personal computer unit
ON
G170
ON/OFF
OFF
CFast unit
CFast
CFAST
FCU8-CF001-001
Stored in
personal computer unit
J303
Network
LAN
J303
GDI
J291
KEYUSB
J070/071
DCIN
24VDC
24VDC
Operation panel I/O unit
FCU8-DX830/837
FG
KEYUSB
DX830:
CJ71
No safety signal input
DX837:
With safety signal input
Safety signal input
SDI
(Safety signal input is
Max. 8 points
DX837 only.)
J210
RIO3
J070/071
DCIN
24VDC
FCU8-MA041/MU042
RIO3
MA041:M850W
GDI
MU042:M830W
J303
Network
LAN
J395/J396
OPTH1
J395/J396
OPTH2
Skip signal input
J100
SKIP
Max. 8 points
RS232C
1ch:J030
device
2ch:J031
SIO
2ch
Analog input : 4 points
J220
AIO
J026/J027
Manual pulse
generator (5V)
Emergency
J120
EMG
stop switch
J070/071
DCIN
24VDC
SD 
memory 
SD
SD
card
Added onto back of
display unit
FCU8-PC231
FCU8-DU181-34
<J09x>
LVDS1
LVDS2
<J190>
<J081>
INV
Backlight
<J290>
I/F PCB
<J420>
USB2-1
<J292>
USB2-2
MENUKEY
USB2-3
USB-RS232C
USB2-4
conversion
USB2-5
USB2-6
USB3-1
USB3-2
Keyboard unit
FCU8-KB04x/KB083
(Note 2)
<G402>
NCKB
5V:J023/J024/J025
12V:J020/J021/J022
MPG
J350/351
CG31
J350/351
CG32
J350/351
CG33
Machine operation
panel made by the
J350/351
CG34
machine tool builder
J120
EMG
Remote I/O unit
24VDC
DI:CJ31/33
DCIN
DO:CJ32/34
RIO3EXT
J210
RIO1
FCU8-DX2xx/DX6xx/DX4xx
MITSUBISHI CNC Machine Operation Panel
FCU8-KB92x
J210
Control unit
24VDC
Remote I/O unit
24VDC
DCIN
DI:CJ31/33
J070/071
DO:CJ32/34
J210
RIO1
RIO1
RIO2
Remote I/O unit
24VDC
DCIN
DI:CJ31/33
J070/071
DO:CJ32/34
J210
RIO2
RIO1
RIO2
RIO4
FCU8-DX2xx/DX6xx /DX4xx
RIO5
RIO6
RIO7
RIO8
Stored in control unit
Function
expansion unit
EXT1
FCU8-EX54x
Function
EXT2
expansion unit
FCU8-EX54x
Communication
expansion unit
EXT3
FCU8-EX56x
Communication
expansion unit
EXT4
FCU8-EX56x
4
Display unit
SD 
memory 
SD
15-type LCD
SD
card
with touch panel
USB
USB
USB memory
Menu key
RS232C
device
Manual pulse
generator (5V/12V)
24VDC
Emergency
stop switch
J350/351
Machine
control
J350/351
relay/contact
RIO2
To the next remote I/O
or terminator connector
(R2-TM)
FCU8-KB941/KB931
<G460>
Remote I/O unit
J350/351
Machine
24VDC
control
J350/351
DCIN
DI:CJ31/33
J070/071
relay/contact
DO:CJ32/34
To the next
RIO1
RIO2
remote I/O or
terminator
connector
(R2-TM)
Remote I/O unit
Machine
24VDC
J350/351
control
DCIN
DI:CJ31/33
J350/351
relay/contact
J070/071
DO:CJ32/34
RIO1
RIO2
To the next
remote I/O or
terminator
Max. 32 units for each port
connector
(R2-TM)
Energy measuring units
(EcoMonitor)