Suspension When Robot's External Operation Authority Gets Invalid - Mitsubishi Electric MELFA BFP-A8787-F Instruction Manual

Iq platform supporting industrial robot
Table of Contents

Advertisement

8Perform Sequencer Direct

(5) Suspension when Robot's External Operation Authority Gets Invalid

When the robot's external operation authority gets invalid while performing the sequencer direct (robot's
dedicated signal - operation authority output (IOENA) is turned OFF), the operation is suspended.
The conditions which make the robot's external operation authority invalid are as follows:
1) The MODE switch is changed from AUTOMATIC to MANUAL on the robot operation panel
(robot is turned servo OFF)
2) The sequencer set the robot's operation authority signal (IOENA) to "OFF"
Sequencer Robot
Command data
- Command No
- Command data 1
- Command data 2
Command
condition data
Command request
Operation authority
(IOENA)
Operation authority
(IOENA)
Command running
Command
completed
Completion status
Command data
- Command No
- Command data 1
- Command data 2
Robot operation
(1) When the robot's external operation authority gets invalid while performing the sequencer direct, the
robot stops, sends "Command running OFF", sets "Completion status" to 30 (suspended), and
sends "Command completed ON".
(2) When the sequencer receives "Command completed ON", the sequencer imports "Completion sta-
tus" and sends "Command request OFF".
(3) When the robot receives "Command request OFF", the robot clears "Completion status" and "Com-
mand data" to zero and sends "Command completed OFF".
2-85 How to Operate Sequencer Direct
1, 100, 0
Override, acceleration, deceleration,
d
MODE switch
AUTO to MANUAL
1, 100, 0
MOV operation
(1)
(2)
(3)
1
30