3. For ITF/CODE39/NW-7
Data length : 57-byte (LP-V series), 54-byte (LP-400/LP-W series)
Data
Name
length
[byte]
Bar code No.
1
Area No.
1
Code type
2
Inversion
1
Check character/
start/stop
1
character
Bar code height
7
Narrow element
5
X position
8
Y position
8
Tilt angle
7
Quiet/
narrow element
4
W
Wide/
narrow element
3
W
Laser power
3
correction
Scan speed
3
correction
(Laser pulse cycle
correction)
(3)
(Only for LP-V
series)
* For the detail of the model type, refer to "Target laser marker" (P.8).
Description
"0"–"7"
"0"–"9", "A"–"F"
"00": CODE39
"01": ITF
"03": NW-7
"0": Do not invert
"1": Invert
• For CODE39, ITF
"0": Check character absence
"1": Check character presence
• For NW-7
"A"–"D": Check character absence
"a"–"d": Check character presence
Model type*
Setting range [mm]
LP-V10
"001.000"–"090.000"
LP-4x0
"001.000"–"110.000"
LP-4x5/LP-V15
"001.000"–"160.000"
LP-4x1/LP-W
"001.000"–"055.000"
"0.050"–"1.000" [mm]
Model type*
Setting range [mm]
LP-V10
"-045.000"–"+045.000"
LP-4x0
"-055.000"–"+055.000"
LP-4x5/LP-V15
"-080.000"–"+080.000"
LP-4x1/LP-W
"-027.500"–"+027.500"
"-180.00"–"+180.00" [°]
"00.0"–"20.0"
"1.8"–"3.4"
"000"–"200" [%]
"005"–"500" [%]
"050"–"200" [%]
ME-LP400V-EX-6
Remarks
Specifies which area part is the marking
position of the concatenated marking on
the flying object.
In case of marking static object, specify
"0".
• For CODE39, ITF, specify the
existence of check character.
• For NW-7, select start and stop
characters from A, B, C and D
and specify the existence of check
character.
Indicates the width of narrow element of
bar and space. Set the larger value than
"Line width" in laser setting screen.
Specifies the center coordinate of the
code.
Ratio of quiet width to narrow element
width.
Ratio of wide element width to narrow
element width.
• The correction ratio is calculated
using the value set at the laser setting
as 100%.
• With LP-400/LP-W series, nothing
should be input in Laser Pulse Cycle
Correction.
99