Count-Up/Count-Down Value Correction - Panasonic LP-400 Series External Control Manual

Laser marker
Hide thumbs Also See for LP-400 Series:
Table of Contents

Advertisement

2-4-7 Count-up/Count-down value correction

SELECT 0 to 2 IN
D0 to D7 IN
(Counter No.)
D8 to D15 IN
(Count-up/count-down
step times)
SET IN
TRIG. IN *3
SET OK OUT *3
READY OUT
MARKING OUT
Item
Time
T1
0ms or more
T2
2 to 510ms
T3
T4
10ms or more
T5
0.5ms or more
*1 : Input SELECT 0 to 2 as the table below.
Number input target
Count-up value correction
Count-down value correction
*2 : Select a value from D0 to D7 for the counter number to correct the count-up/count-down value. Specify a value in D8
to D15 for the step times of count-up or count-down in the binary system. Refer to "Operation of input signal on I/O
connector" (P.34) for the detail.
*3 : To input "SET" signal during the marking operation as a next counter data, do not input "SET" until "MARKING" output
is turned ON.
50
ON
*1
*1
OFF
ON
*2
*2
OFF
ON
*2
*2
OFF
ON
T5
OFF
T1
ON
OFF
ON
T2
OFF
ON
OFF
ON
OFF
Remarks
Keep the input until the SET OK is turned to ON.
One-shot output. Set the output time on the environment setting screen.
There is a margin for the setting value.
• When laser pumping is completed
Period for creating marking data. It varies depending on the quantity of data to be
marked.
• When laser pumping is not completed
Period for creating marking data or period until the laser pumping is completed. The
longer one of the two above is employed.
Keep the ON status for 10ms or more.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN
to D15 IN, turn on SET IN.
SELECT 0 (No. 20)
OFF
ON
ME-LP400V-EX-6
T4
T3
SELECT 1 (No. 21)
SELECT 2 (No. 22)
ON
ON
OFF
OFF

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents