GE N60 Instruction Manual page 478

Ur series network stability and synchrophasor measurement system
Hide thumbs Also See for N60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 36 of 65)
ADDR
REGISTER NAME
(8-bit) Switch (Read/Write Setting) (6 modules)
82C0
Switch 1 Function
82C1
Switch 1 Argument A Bits (8 items)
82D1
Switch 1 Argument B Bits (8 items)
82E1
Switch 1 Control
B
82E3
Reserved (6 items)
82E9
...Repeated for Switch 2
8312
...Repeated for Switch 3
833B
...Repeated for Switch 4
8364
...Repeated for Switch 5
838D
...Repeated for Switch 6
Direct Integers (Read/Write Setting) (16 modules)
8540
Direct Integer Output 1 Value
8541
Direct Integer Output 1 Trigger
8543
Direct Integer Input 1 Device
8544
Direct Integer Input 1 Number
8545
Direct Integer Input 1 Default Value
8547
Direct Integer Input 1 Mode
8548
Direct Integer Reserved
854A
...Repeated for Direct Integer Output 2
8554
...Repeated for Direct Integer Output 3
855E
...Repeated for Direct Integer Output 4
8568
...Repeated for Direct Integer Output 5
8572
...Repeated for Direct Integer Output 6
857C
...Repeated for Direct Integer Output 7
8586
...Repeated for Direct Integer Output 8
8590
...Repeated for Direct Integer Output 9
859A
...Repeated for Direct Integer Output 10
85A4
...Repeated for Direct Integer Output 11
85AE
...Repeated for Direct Integer Output 12
85B8
...Repeated for Direct Integer Output 13
85C2
...Repeated for Direct Integer Output 14
85CC
...Repeated for Direct Integer Output 15
85D6
...Repeated for Direct Integer Output 16
FlexState Settings (Read/Write Setting)
8800
FlexState Parameters (256 items)
Digital Elements (Read/Write Setting) (48 modules)
8A00
Digital Element 1 Function
8A01
Digital Element 1 Name
8A09
Digital Element 1 Input
8A0B
Digital Element 1 Pickup Delay
8A0D
Digital Element 1 Reset Delay
8A0F
Digital Element 1 Block
8A11
Digital Element 1 Target
8A12
Digital Element 1 Events
8A13
Digital Element 1 Pickup LED
8A14
Reserved (2 items)
8A16
...Repeated for Digital Element 2
8A2C
...Repeated for Digital Element 3
8A42
...Repeated for Digital Element 4
8A58
...Repeated for Digital Element 5
8A6E
...Repeated for Digital Element 6
8A84
...Repeated for Digital Element 7
8A9A
...Repeated for Digital Element 8
B-44
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 1
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 65535
---
0 to 65535
---
0 to 4294967295
---
0 to 16
---
0 to 16
---
0 to 4294967295
---
0 to 1
---
0 to 65535
---
0 to 4294967295
---
0 to 1
---
---
---
0 to 4294967295
---
0 to 999999.999
s
0 to 999999.999
s
0 to 4294967295
---
0 to 2
---
0 to 1
---
0 to 1
---
---
---
APPENDIX B
STEP
FORMAT
DEFAULT
1
F102
0 (Disabled)
1
F300
0
1
F300
0
1
F300
0
1
F001
0
1
F612
0
1
F300
0
1
F001
0
1
F001
0
1
F003
1000
1
F491
0 (Default Value)
1
F003
0
1
F300
0
1
F102
0 (Disabled)
---
F203
"Dig Element 1"
1
F300
0
0.001
F003
0
0.001
F003
0
1
F300
0
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F102
1 (Enabled)
---
F001
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents