APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 23 of 65)
ADDR
REGISTER NAME
4447
User Programmable SNTP Fail Function
4448
User Programmable IRIG-B Fail Function
4449
User Programmable Ethernet Switch Fail Function
444A
Process Bus Failure Operand
444C
PTP Fail Function
444D
User Programmable Third Ethernet Fail Function
444E
User Programmable SFP Fail Function
CT Settings (Read/Write Setting) (6 modules)
4480
Phase CT 1 Primary
4481
Phase CT 1 Secondary
4482
Ground CT 1 Primary
4483
Ground CT 1 Secondary
4484
...Repeated for CT Bank 2
4488
...Repeated for CT Bank 3
448C
...Repeated for CT Bank 4
4490
...Repeated for CT Bank 5
4494
...Repeated for CT Bank 6
VT Settings (Read/Write Setting) (6 modules)
4500
Phase VT 1 Connection
4501
Phase VT 1 Secondary
4502
Phase VT 1 Ratio
4504
Auxiliary VT 1 Connection
4505
Auxiliary VT 1 Secondary
4506
Auxiliary VT 1 Ratio
4508
...Repeated for VT Bank 2
4510
...Repeated for VT Bank 3
4518
...Repeated for VT Bank 4
4520
...Repeated for VT Bank 5
4528
...Repeated for VT Bank 6
Source Settings (Read/Write Setting) (6 modules)
4580
Source 1 Name
4583
Source 1 Phase CT
4584
Source 1 Ground CT
4585
Source 1 Phase VT
4586
Source 1 Auxiliary VT
4587
...Repeated for Source 2
458E
...Repeated for Source 3
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
4601
Phase Rotation
4602
Frequency and Phase Reference
4603
Frequency Tracking Function
Breaker Control (Read/Write Settings) (6 modules)
47D0
Breaker 1 Function
47D1
Breaker 1 Name
47D4
Breaker 1 Mode
47D5
Breaker 1 Open
47D7
Breaker 1 Close
47D9
Breaker 1 Phase A / Three-pole Closed
47DB
Breaker 1 Phase B Closed
47DD
Breaker 1 Phase C Closed
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 1
---
0 to 1
---
0 to 1
---
0 to 4294967295
---
0 to 1
---
0 to 1
---
0 to 1
---
1 to 65000
A
0 to 1
---
1 to 65000
A
0 to 1
---
0 to 1
---
25 to 240
V
1 to 24000
:1
0 to 6
---
25 to 240
V
1 to 24000
:1
0 to 1
---
0 to 63
---
0 to 63
---
0 to 63
---
0 to 63
---
25 to 60
Hz
0 to 1
---
0 to 5
---
0 to 1
---
0 to 1
---
---
---
0 to 1
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
B.4 MEMORY MAPPING
STEP
FORMAT
DEFAULT
1
F102
1 (Enabled)
1
F102
1 (Enabled)
1
F102
1 (Enabled)
1
F300
0
1
F102
1 (Enabled)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F001
1
1
F123
0 (1 A)
1
F001
1
1
F123
0 (1 A)
1
F100
0 (Wye)
0.1
F001
664
1
F060
1
1
F166
1 (Vag)
0.1
F001
664
1
F060
1
1
F206
"SRC 1"
1
F400
0
1
F400
0
1
F400
0
1
F400
0
1
F001
60
1
F106
0 (ABC)
1
F167
0 (SRC 1)
1
F102
1 (Enabled)
1
F102
0 (Disabled)
---
F206
"Bkr 1"
1
F157
0 (3-Pole)
1
F300
0
1
F300
0
1
F300
0
1
F300
0
1
F300
0
B-31
B