B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 10 of 65)
ADDR
REGISTER NAME
26BE
IEC 61850 GGIO5 uinteger Input 15 Operand
26BF
IEC 61850 GGIO5 uinteger Input 16 Operand
IEC 61850 Received Integers (Read Only Actual Values) (16 modules)
26F0
IEC 61850 Received uinteger 1
26F2
IEC 61850 Received uinteger 2
B
26F4
IEC 61850 Received uinteger 3
26F6
IEC 61850 Received uinteger 4
26F8
IEC 61850 Received uinteger 5
26FA
IEC 61850 Received uinteger 6
26FC
IEC 61850 Received uinteger 7
26FE
IEC 61850 Received uinteger 8
2700
IEC 61850 Received uinteger 9
2702
IEC 61850 Received uinteger 10
2704
IEC 61850 Received uinteger 11
2706
IEC 61850 Received uinteger 12
2708
IEC 61850 Received uinteger 13
270A
IEC 61850 Received uinteger 14
270C
IEC 61850 Received uinteger 15
270E
IEC 61850 Received uinteger 16
Direct Integer Actual Values (Read Only) (16 modules)
2730
Direct Integer Input 1 Actual Value
2732
Direct Integer Input 2 Actual Value
2734
Direct Integer Input 3 Actual Value
2736
Direct Integer Input 4 Actual Value
2738
Direct Integer Input 5 Actual Value
273A
Direct Integer Input 6 Actual Value
273C
Direct Integer Input 7 Actual Value
273E
Direct Integer Input 8 Actual Value
2740
Direct Integer Input 9 Actual Value
2742
Direct Integer Input 10 Actual Value
2744
Direct Integer Input 11 Actual Value
2746
Direct Integer Input 12 Actual Value
2748
Direct Integer Input 13 Actual Value
274A
Direct Integer Input 14 Actual Value
274C
Direct Integer Input 15 Actual Value
274E
Direct Integer Input 16 Actual Value
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Contact Input/Output States (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (32 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
B-18
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
---
---
---
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 65535
---
0 to 65535
---
0 to 400000000
---
0 to 65535
---
0 to 1
---
0 to 1
---
APPENDIX B
STEP
FORMAT
DEFAULT
---
F612
0
---
F612
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F003
0
1
F108
0 (Off)
1
F108
0 (Off)
1
F108
0 (Off)
1
F108
0 (Off)
1
F155
0 (Offline)
1
F108
0 (Off)
1
F001
0
1
F001
0
1
F050
0
1
F001
0
1
F126
0 (No)
1
F126
0 (No)