For switching between the RS-232 connection and the RS-422 connection, make sure to turn off the Handy GOT
power before disconnecting or connecting the cable connector for PLC communication in the environmental protection
back cover.
Disconnecting or connecting the cable connector without turning off the Handy GOT power causes a failure.
The selected connection method (RS-232 connection or RS-422 connection) is applied when the Handy GOT power is
turned on.
The connector can be checked through the window when the environmental protection back cover is closed.
It can be used as a method to check the connection type from the outside of Handy GOT.
7.3.1

Installing and removing of external cable

■1. Installation procedure of external cable
Step 1.
Make sure that the GOT power is off.
Step 2.
Insert the connector adjusting the triangle marks of the main unit side connector and cable side connector.
Step 3.
After inserting the connector, push the lock lever.
The connecters are locked after the lever is pushed into.
Environmental protection
back cover window
7.3 Overview of Communication Cable
7
7 - 21