8.2.4

Connecting to UTAdvanced Series

When using the RS232C/RS485 converter
UTAdvanced
series
Temperature
Connection cable 1)
controller
Cable model
Series
Connection diagram
number
RS485 connection
UT32A
diagram 19)
UT35A
(4-wire type)
*2
UT55A
UT75A
UP35A
*3
UP55A
RS485 connection
*4
UM33A
diagram 20)
(2-wire type)
UT52A
RS485 connection
*5
UT55A
diagram 12)
*6
UP55A
(2-wire type)
*7
UM33A
*1
Product manufactured by YOKOGAWA Electric Corporation. For details of the product, contact Yokogawa Electric Corporation.
For *2 to *7, only the products that meet the following conditions can be connected.
Annotation
RS232C
UTAdvanced
/RS485
series
converter
Connection cable 1)
RS232C/RS485
*1
converter
Commun
Max.
Model
ication
distance
name
Type
1200m
RS-232
ML2-
1200m
RS-232
ML2-
1200m
RS-232
ML2-
Suffix code
Function
Open network
1 or 2
-
*2
-
1
2
-
Other than 3
-
*3
-
-
-
-
*4
1
-
*5
1 or 2
-
2
-
*6
-
-
*7
1
-
8. CONNECTION TO YOKOGAWA TEMPERATURE CONTROLLER
Connection cable 2)
Connection cable 2)
Cable model
Max.
Connection diagram number
distance
GT09-C30R20304-9S (3m)
or
15m
RS232 connection
diagram 1)
GT09-C30R20304-9S (3m)
or
15m
RS232 connection
diagram 1)
GT09-C30R20304-9S (3m)
or
15m
RS232 connection
diagram 1)
Optional suffix code
Product with two RS-485 communication ports (4-wire type/
Without "/LP"
2-wire type) and without the power supply for 24VDC sensor
Product with the open network port of RS-485
-
communication (4-wire type/2-wire type)
Product with two RS-485 communication ports (4-wire type/
-
2-wire type) (Standard code model)
Product without the additional contact output points (DO)
-
and with the open network port of RS-485 communication
(4-wire type/2-wire type) (Standard code model)
Product with RS-485 communication port (4-wire type/2-wire
With "/CH3"
type) specified in the E3 terminal area option (Detailed code
model)
Product with the RS-485 communication port (4-wire type/2-
With "/C4"
wire type) specified in the E4 terminal area option (Detailed
code model)
Product with two RS-485 communication ports (4-wire type)
Without "/LP"
and without the power supply of 24VDC sensor
Product with two RS-485 communication ports (4-wire type/
With "/LP"
2-wire type) and with the power supply for 24VDC sensor
Product with two RS-485 communication ports (4-wire type/
-
2-wire type) (Standard code model)
Product with the RS-485 communication port (4-wire type/2-
With "/C4"
wire type) specified in the E4 terminal area option (Detailed
code model)
Product with two RS-485 communication ports (4-wire type/
With "/LP"
2-wire type) and with the power supply for 24VDC sensor
8.2 System Configuration
Communication driver
GOT
YOKOGAWA GREEN/UT100/
UT2000/UTAdvanced
GOT
Number of
connectable
equipment
Option device
Model
Up to 31
- (Built into
temperature
GOT)
controllers
for 1 GOT
GT15-RS2-9P
Up to 31
- (Built into
temperature
GOT)
controllers
for 1 GOT
GT15-RS2-9P
Up to 31
- (Built into
temperature
GOT)
controllers
for 1 GOT
GT15-RS2-9P
Remark
1
2
3
4
5
6
7
8
8 - 7

Advertisement

Table of Contents
loading

Table of Contents