■Structure member
When the structure member is a structure type, specify the element name by delimiting with period '.' up to the end member.
Ex.
When specifying the member, 'memberB1', of the structure member name 'memberA3' for the structure type label name
'LabelA'
• Label name character string: LabelA.memberA3.memberB1
When arbitrary device is assigned, the structure type label with structure type members cannot be specified.
Timer type label, counter type label
The labels of the following data types are handled as a structure with a contact, coil, and current value for its element.
• Timer
• Retentive timer
• Counter
• Long timer
• Long retentive timer
• Long counter
Specify the following element name with adding a period '.'. (UTF-16: '.' = 002E)
Item
Element name
Contact
S
Coil
C
Current value
N
Ex.
For the contact of timer type label name 'Lbl1'
• Label name length: 6H
• Label name character string: Lbl1.S
Item
Value of code corresponds to character
Label name
L
UTF-16
004C
ASCII code
30303443
Binary code
4C00
The labels of which data type is timer, counter, retentive timer, long timer, long counter, or long retentive timer
cannot be specified with the 'batch read/write array type labels' (command: 041A, 141A).
9 LABEL ACCESS
128
9.1 Data to be Specified in Commands
Example when a label name is 'Lbl1'
Lbl1.S
Lbl1.C
Lbl1.N
b
l
1
0062
006C
0031
30303632
30303643
30303331
6200
6C00
3100
.
S
002E
0053
30303245
30303533
2E00
5300