Turn COM.ERR. LED OFF (command: 1617)
Turn the COM.ERR.LED of Ethernet interface module OFF.
The commands can be used for E71 connected to an external device and cannot be used via network.
Message format
The following shows the message format of the request data and response data of the command.
■Request data
Command
Subcommand
■Response data
There is no response data for this command.
Data specified by request data
■Command
ASCII code
1
6
1
7
31
36
31
37
H
H
H
H
■Subcommand
ASCII code
0
0
0
0
30
30
30
30
H
H
H
H
Communication example
Turn COM.ERR.LED OFF.
■Data communication in ASCII code
(Request data)
Subcommand
1
6
1
7
0
0
0
0
31
36
33
31
30
30
30
30
H
H
H
H
H
H
H
H
■Data communication in binary code
(Request data)
Subcommand
17
16
00
00
H
H
H
H
Binary code
17
16
H
H
Binary code
00
00
H
H