Clear Error Information; Turn Indicator Led Off, Initialize Error Code (Command: 1617) - Mitsubishi Electric MELSEC IQ-R series Reference Manual

Programmable controller
Hide thumbs Also See for MELSEC IQ-R series:
Table of Contents

Advertisement

11.5

Clear Error Information

This section explains the command to initialize LED display and error information of buffer memory, and recover the
supported device.
For details of the related LEDs, input/output signals, and buffer memory, refer to the manual of the access target module.

Turn indicator LED OFF, initialize error code (command: 1617)

Turn OFF the indicator LED of the serial communication module, and initialize the communication error information and error
codes.
The command can only be used for C24 (including multidrop connection station) connected to the external
device. It cannot be used via network.
Message format
The following shows the message format of the request data and response data of the command.
■Request data
Command
Subcommand
■Response data
There is no response data for this command.
Data specified by request data
■Command
ASCII code
1
6
1
7
31
36
31
37
H
H
H
H
Communication error
Communication error
information (CH1)
information (CH2)
Binary code
17
16
H
H
11 CONTROL MODULE OPERATION
11.5 Clear Error Information
11
187

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsecq seriesMelsec l series

Table of Contents