Lubricating The Machine - Toro 09802 HydroJect 3010 Operator's Manual

Hide thumbs Also See for 09802 HydroJect 3010:
Table of Contents

Advertisement

Caution
If you leave the key in the ignition switch, someone
could accidently start the engine and seriously
injure you or other bystanders.
Remove the key from the ignition and disconnect
the wire from the spark plug before you do any
maintenance. Set the wire aside so that it does not
accidentally contact the spark plug.
Caution
Contact with hot surfaces could cause burns.
Wait for the unit to cool before servicing or
making adjustments to the machine.

Lubricating the Machine

The aerator has 5 grease fittings that must be lubricated
every 50 hours of operation with No. 2 General Purpose
Lithium Base Grease. Lubricate all fittings immediately
after every washing, regardless of the interval listed.
The bearings and bushings that must be lubricated are:
steering pivot shaft (Fig. 15), limit switch housing (Fig. 16)
(2) lift arm shaft (Fig. 16), and neutral pivot shaft (Fig. 17).
Figure 15
1. Wipe the grease fitting clean so that foreign matter
cannot be forced into the bearing or bushing.
2. Pump grease into the bearing or bushing.
3. Wipe up excess grease.
25
Figure 16
Figure 17