Checking The Pump Case Fluid Level; Checking The Tire Pressure; Checking The Accumulator Charge - Toro 09802 HydroJect 3010 Operator's Manual

Hide thumbs Also See for 09802 HydroJect 3010:
Table of Contents

Advertisement

Checking the Pump Case Fluid
Level
The pump crank case is filled at the factory with
approximately 40 ounces of Mobil DTE Extra Heavy oil.
Check the oil level on the dipstick before the engine is first
started and daily thereafter. Change the oil initially after
25 hours of operation, thereafter change every 200 hours
of operation. See the chart below for equivalent oils.
Shell
Chevron
Conoco
Exxon
Philllips
Sun
76 Lubricants
Castrol
Important
The oil must be changed immediately when
any contamination, sludge, water, or condensation appears
in the oil. Determine and correct any oil contamination
problem before restarting the engine and operating the
machine.
1. Position the machine on a level surface.
2. Release the hood latches and raise the hood.
3. Remove the dipstick/filler cap and check the oil level on
the dipstick. The fluid level should be up to the FULL
mark (Fig. 6).
Figure 6
1. Dipstick/filler cap
Morlina Sd 150
AW Machine Oil 150
Multipurpose R&O
0.1 150
Terresstic 150
Magnus Oil 150
Sunvis 150
Turbine Oil 150
Paradene 150 R&O
1
FULL
4. If the fluid level is low, add enough Mobil DTE Extra
Heavy oil or equivalent oil to bring the oil up to the
proper level. Do not overfill.
5. Lower the hood and secure the latches.

Checking the Tire Pressure

The tires are over inflated for shipping. Make sure that the
front and rear tires are inflated to 8 to 12 p.s.i. (55 to
83 kPa).
Checking the Accumulator
Charge
Have the accumulator charge checked before and after each
operating season by an Authorized Toro Distributor.
Charge accumulators contain high pressure
nitrogen. Nitrogen is the only gas to use for
accumulator charging. Installing improper gases in
an accumulator can cause an explosion and death.
Charging requires special tools and precautions.
• Charge the accumulator in a well ventilated
area.
• Have the accumulator checked and charged by
an Authorized Toro Distributor.
• Wear eye protection.
• Keep your hands and face away from the gas
valve.
Failure to open the bleed valve before servicing
high pressure water components can cause
personal injury, dismemberment, or death.
Slowly open the high pressure water bleed valve
before servicing any component connected to the
high pressure water system. Opening the high
pressure bleed valve allows any trapped water to
escape from the system and also allows the
accumulator piston to move to the bottom of the
accumulator cylinder.