Lubricating the Machine
The aerator has 5 grease fittings that must be lubricated
every 50 hours of operation with No. 2 General Purpose
Lithium Base Grease. Lubricate all fittings immediately
after every washing, regardless of the interval listed.
The bearings and bushings that must be lubricated are:
steering pivot shaft (Figure 18), limit switch housing
(Figure 19) (2) lift arm shaft (Figure 19), and neutral
pivot shaft (Figure 20).
1. Wipe the grease fitting clean so that foreign matter
cannot be forced into the bearing or bushing.
2. Pump grease into the bearing or bushing.
3. Wipe up excess grease.
Figure 18
Figure 19
25
Figure 20