Mitsubishi Electric F700 Instruction Manual page 125

Fr-f720-0.75k to 110k; fr-f740-0.75k to 560k
Hide thumbs Also See for F700:
Table of Contents

Advertisement

Types of Monitor
Increments
Converter output
0.1V
voltage
Regenerative
0.1%
brake duty
Electronic thermal
relay function load
0.1%
factor
Output current
0.01A/0.1A
peak value
*5
Converter output
0.1V
voltage peak value
0.01kW/
Input power
0.1kW
*5
0.01kW/
Output power
0.1kW
*5
Load meter
0.1%
Cumulative
1h
energization time
*2
Reference voltage
output
Actual operation
1h
time 
*2*3
Motor load factor
0.1%
0.01kWh/
Cumulative power
0.1kWh
*4, *5
Power saving
Variable
effect
according
to
Cumulative saving
parameters
power
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
terminal status
Option output
terminal status
Pr. 52 Parameter
Pr. 54 (FM)
Setting Value
Pr. 158 (AM)
Parameter
PU main
Setting
DU LED
monitor
Value
8
8
*1
9
9
*1
10
10
*1
11
11
*1
12
12
*1
13
13
*1
14
14
*1
17
17
×
20
21
×
23
24
24
×
25
50
50
×
51
52
52
53
53
×
54
×
*1
55
×
*1
×
×
56
×
×
57
Monitor display and monitor output signal
Full-scale
value of the
terminal FM
and AM
200V
class:400V
Displays the DC bus voltage value.
400V
class:800V
Brake duty set in Pr. 30 and Pr. 70 (Setting
Pr. 70
can be made for the 75K or more.)
Displays the motor thermal cumulative value
100%
on the assumption that the thermal operation
level is 100%.
Retain the peak value of the output current
Pr. 56
monitor and display (clears at every start)
200V
class:400V
Retain the peak value of the DC bus voltage
400V
value and display (clears at every start)
class:800V
Rated
inverter
Displays power of the inverter input side
×
power
2
Rated
inverter
Displays power of the inverter output side
×
power
2
Torque current is displayed in % on the
100%
assumption that the Pr. 56 setting is 100%
Cumulative energization time since the
inverter shipment is displayed
You can check the numbers of the monitor
value exceeded 65535h with Pr. 563.
Terminal FM:1440 pulse/s is output
Terminal AM: 10V is output
Cumulative inverter running time is displayed.
You can check the numbers of the monitor
value exceeded 65535h with Pr. 564.
Use Pr. 171 to clear the value.
(Refer to page 120 .)
On the assumption that the rated inverter
current value is 100%, the output current
value is displayed in %.
200%
Monitor value = loutput current monitor
value/rated inverter current
Cumulative power amount is displayed
according to the output power monitor
Use Pr. 170 to clear the value.
(Refer to page 120.)
Inverter
Displays energy saving effect monitor
capacity
You can change the monitor to power saving,
power saving average value, charge display
and % display using parameters.
(For details, refer to page 138.)
100%
Displays the set point, measured value and
100%
deviation during PID control
(For details, refer to page 206.)
ON/OFF status of the input terminal is
displayed on the PU
(Refer to page 119 for DU display)
ON/OFF status of the output terminal is
displayed on the PU
(Refer to page 119 for DU display)
ON/OFF status of the input terminal of the
digital input option (FR-A7AX) is displayed
on the DU (refer to page 119 for details)
ON/OFF status of the output terminal of the
digital output option (FR-A7AY) and relay
output option (FR-A7AR) is displayed on the
DU (refer to page 119 for details)
Description
×
100 [%]
117
4