Removal (Fig. 70)
1. Read the General Precautions for Removing and
Installing Hydraulic System Components at the begin-
ning of the Service and Repairs section of this chapter.
2. To prevent contamination of hydraulic system during
manifold removal, thoroughly clean exterior of manifold
and fittings.
3. Disconnect hydraulic lines from manifold and put
caps or plugs on open hydraulic lines and fittings. Label
disconnected hydraulic lines for proper reassembly.
4. Remove filter manifold from the frame using Figure
70 as guide.
5. If hydraulic fittings are to be removed from manifold,
mark fitting orientation to allow correct assembly. Re-
move fittings from manifold and discard O--rings.
Groundsmaster 4100--D/4110--D
Installation (Fig. 70)
1. If fittings were removed from manifold, lubricate and
place new O--rings onto fittings. Install fittings into man-
ifold openings using marks made during the removal
process to properly orientate fittings. Tighten fittings
(see Hydraulic Fitting Installation in the General Infor-
mation section of this chapter).
2. Install filter manifold to the frame using Figure 70 as
guide.
3. Remove caps and plugs from fittings and hoses. Us-
ing labels placed during manifold removal, properly con-
nect hydraulic lines to manifold (see Hydraulic Hose and
Tube Installation in the General Information section of
this chapter).
4. Make sure hydraulic tank is full. Add correct oil if nec-
essary before returning machine to service.