Honeywell XYR 400E User Manual page 27

Wireless ethernet modem
Table of Contents

Advertisement

My Right Boot 2.1
Copyright 1999-2004 Cybertec Pty Ltd, All rights reserved.
This software is provided by Cybertec ``as is'' and with NO WARRANTY.
http://www.cybertec.com.au/
ROM :
256KB @ 0xffe00000
RAM :
8192KB @ 0x00000000 (143KB / 0x00023d8c)
ROM Configuration table ... PASSED.
RAM address pattern check . PASSED.
RAM address bus check ..... PASSED.
Product
: E24g
Variant
: E2400-100
Serial No.
: 07050012 - 03061081212
Release
: epm_mrb_elpro_E24g_1.63
Released date : 1 March 2006
Released host : Anxosity
Build date
: Tue Mar
Build host
: Anxosity
Boot Flags
: no RAM test, no ROM test, bus timer on, wdog on
Boot delay
: 0
Boot Filename : /memory/0xffe40000,0x80000
Boot Address
: 192.168.0.112
Boot Netmask
: 255.255.255.0
Boot Gateway
: 192.168.0.1
Boot Host
: 192.168.0.220
Boot Mac 0
: 00:12:af:00:03:05
Boot Mac 1
: 00:12:af:00:03:05
RTE data store .... no error
Setting bus timer (on) and watchdog (on) ... PASSED
802.11 Interface Power ON...
Reset 802.11 Interface...
Checking 802.11 NIC (Base Address: 0x30000000)
Register Read-Write Test...OK
Initialising..Successful
Getting Serial Number..Reading Buffer..
Serial Number: 99SA01000000
Done..
Recovery Configuration :
ip address : 192.168.0.112
net mask
: 255.255.255.0
gateway
: 192.168.0.1
host
: 192.168.0.1
eip: mount point /memory
fec0: connected at 10M Half Duplex.
fec0: local ip = 192.168.0.112, server ip = 192.168.0.1
Press ENTER to abort automatic booting ... 5
e) Check values for Boot Address, Boot Netmask, and Boot Gateway. These values should be set
to reflect those of the PC you are using to configure the unit. If these are correct skip to step (h).
You may check settings again with the rct command. For further help, type the help command.
f)
Set Boot Netmask to the same settings as the computer you have the Ethernet cable connected
to. This may be performed with the command: bnm <Type the netmask>
g) Set Boot Gateway to the same settings as the computer you have the Ethernet cable connected
to. This may be performed with the command: bgw <Type the gateway IP address>
h) Choose an IP address for the XYR 400E being upgraded. This IP address must be on the same
network as the computer you have connected the Ethernet cable to. This may be performed with
the command: bip <Type the IP address>
27
7 08:50:31 2006
static IP, auto-boot, net-boot, reset on
local file, no binary load
XYR400E Ethernet Modem
Version 1
5/1/08

Advertisement

Table of Contents
loading

Table of Contents