SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS
SOUND
CAUSE
INTERRUPTED
FIRE ALARM (3 beeps)
OR
CARBON MONOXIDE ALARM (4 beeps)
CONTINUOUS
BURGLARY/AUDIBLE EMERGENCY
ALARM
ONE SHORT BEEP
a. SYSTEM DISARM
(not repeated)
b. SYSTEM ARMING ATTEMPT WITH
AN OPEN ZONE.
c. BYPASS VERIFY
ONE SHORT BEEP
a. SYSTEM IS IN TEST MODE
(once every 45 secs)
b. LOW BATTERY AT A TRANSMITTER
c. SYSTEM LOW BATTERY
d. FAIL TO COMMUNICATE
TWO SHORT
ARM AWAY
BEEPS
THREE SHORT
a. ARM STAY OR INSTANT
BEEPS
b. ZONE OPENED WHILE SYSTEM IS IN
CHIME MODE.
RAPID BEEPING
a. TROUBLE
b. MEMORY OF ALARM
SLOW BEEPING
a. ENTRY DELAY WARNING
b. EXIT DELAY WARNING
Additional Announcements:
The system will announce the following primary messages, depending on the system's status
at the time:
Disarmed–Ready to Arm [check system]
Disarmed [not ready to arm]
Armed [away] [stay] [instant] [check system] [exit now]
The system will announce the following secondary messages, depending on the system's
status at the time:
Fire Alarm + zone voice descriptor
Alarm + zone voice descriptor
Carbon Monoxide Alarm + zone voice descriptor
Carbon Monoxide Fault + zone voice descriptor
Fire Fault + zone voice descriptor
Fault + zone voice descriptor Alarm + zone voice descriptor
Low Battery + zone voice descriptor Fire Fault + zone voice descriptor
System Low Battery
Check System
Check Zone
Activity Detected + zone type
AC Loss
Zones Bypassed
Chime
Note: If there are no secondary messages, the primary status messages will be announced.
ANNOUNCEMENT*
fire alarm + zone voice descriptor
OR
Carbon monoxide alarm + zone voice descriptor
(Voice descriptor is interlaced with the sounder
and sounds every 45 seconds)
alarm + zone voice descriptor
(Voice descriptor is interlaced with the sounder
and sounds every 45 seconds)
a. disarmed–ready to arm
b. disarmed–not ready to arm
c. zones bypassed
a. no announcement
b. low battery + zone voice descriptor
c. system low battery
d. check system
armed away [instant] – exit now
a. armed stay [instant] – exit now
b. zone voice descriptor
a. fault + zone voice descriptor
b. fire alarm or alarm + zone voice descriptor
a. disarm system now
b. armed [away] [instant] – exit now
– 79 –