Summary Of Audible/Visual Notifications - Honeywell LXL-1000 User Manual

Table of Contents

Advertisement

Summary of Audible/Visual Notifications

SOUND
LOUD,
INTERRUPTED *
Keypad & Ext.
LOUD,
CONTINUOUS *
Keypad & Ext.
ONE SHORT
BEEP
(not repeated)
Keypad only
ONE SHORT
BEEP
(every 40 secs)
Keypad only
TWO SHORT
BEEPS
Keypad only
THREE SHORT
BEEPS
Keypad only
RAPID
BEEPING
Keypad only
SLOW
BEEPING
Keypad only
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 48 –
www.PDF-Zoo.com
Fixed-Word Display Keypads
CAUSE
FIRE ALARM
BURGLARY/AUDIBLE
EMERGENCY ALARM
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
a. SYSTEM IS IN TEST MODE
b. LOW BATTERY AT A
TRANSMITTER
ARM AWAY or MAXIMUM
a. ARM STAY, NIGHT-STAY,
INSTANT
b. ZONE OPENED WITH
SYSTEM IN CHIME MODE.
a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
FAIL
a. EXIT DELAY WARNING
b. ENTRY DELAY WARNING
DISPLAY
FIRE is displayed; zone number of zone in
alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be
displayed.
ALARM is displayed. Zone number of zone
in alarm is also displayed.
a. READY indicator light comes on.
b. Number of the open protection zone
displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS is displayed.
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
transmitter.
AWAY is displayed. Red ARMED indicator is
lit.
a. STAY or INSTANT is displayed. Red
ARMED indicator is lit.
b. CHIME displayed; zone number of open
protection zone will be displayed if the [✱]
key is pressed.
a. CHECK displayed. Zone number of
troubled protection zone is displayed.
b. FIRE or ALARM is displayed; zone
number of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70 is displayed.
a. AWAY is displayed.
b. Exceeding the entry delay time without
disarming causes alarm.