Offline Dm Verification Of The Boot Configuration Record And Disk - Cisco CSS 11501 - Content Services Switch Getting Started Manual

11500 series content services switch
Table of Contents

Advertisement

Appendix A
Troubleshooting the Boot Process
Table A-1
Field
Test_name
Failure_details
After the CSS performs the diagnostics, it boots the Offline DM as indicated by
the following message:
Booting OffDm @ 0xbfd70000
See the
section for the Offline DM verification of the boot configuration record and disk
drive.
If the Booting OffDm message does not appear, a CSS 11501 component failure
or an SCM failure may have occurred; such a failure would not allow a software
download to start.
If this problem occurs for a CSS 11501, contact Cisco Technical Assistance
Center (TAC) for technical assistance.
If this problem occurs for a CSS 11503 or CSS 11506:
1.
2.
3.
If reseating the module does not correct the failure, contact TAC for technical
assistance.
OL-6037-01
Fields in the Diagnostic Monitor Error Message (continued)
Description
Provides the name of the test reporting the error. For
example:
Uart Interrupt Test
PHY Reset Test
Provides information about the error. For example:
PHY Reset Register failed to clear. Addr: 0x12345678
Expected: 0x0 Actual:0xf

"Offline DM Verification of the Boot Configuration Record and Disk"

Power down the CSS.
Reseat the SCM.
Power up the CSS.
Diagnostic Tests for Hardware and Error Messages
Cisco Content Services Switch Getting Started Guide
A-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Css 11506Css 1150111503 - css content services switch