Installation

Electrical connection

The oven is equipped with a mains con-
nection cable and plug for connection to
a 50 Hz, 230 V alternating current sup-
ply.
The fuse rating must be at least 16 A.
The appliance must only be connected
to a correctly installed earthed socket.
The electrical installation must comply
with VDE 0100 requirements.
Ensure that the plug and switch are ac-
cessible at all times.
If the appliance is hardwired or if the
switch is not accessible after installa-
tion, an additional means of disconnec-
tion means must be provided.
Suitable means of disconnection in-
clude accessible switches with an all-
pole contact gap of at least 3 mm.
These include circuit breakers, fuses
and contactors (EN 60335).
Connection data is given on the data
plate situated at the front of the oven
compartment. Please ensure the con-
nection data matches the household
supply.
When contacting Miele, please quote
the following:
- Model identifier
- Serial number
- Connection data (mains voltage/fre-
quency/maximum rated load)
If the mains connection cable is dam-
aged, a new one must be fitted by a ser-
vice technician authorised by the Miele
Customer Service Department.
This compact microwave combination
oven complies with European standard
EN 55011. It is classified as a Group 2,
class B appliance.
102
Group 2 appliances use high frequency
energy in the form of electromagnetic
waves to create heat in food.
Class B is assigned to appliances that
are suitable for domestic use.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not syn-
chronised with the mains power supply
(e.g. island networks, back-up systems)
is possible. A prerequisite for operation
is that the power supply system com-
plies with the specifications of
EN 50160 or an equivalent standard.
The function and operation of the pro-
tective measures provided in the do-
mestic electrical installation and in this
Miele product must also be maintained
in isolated operation or in operation that
is not synchronised with the mains
power supply, or these measures must
be replaced by equivalent measures in
the installation. As described, for ex-
ample, in the current version of
VDE-AR-E 2510-2.