Honeywell BENDIX/KING KAP 140 Maintenance Manual page 99

Flight control system
Hide thumbs Also See for BENDIX/KING KAP 140:
Table of Contents

Advertisement

ERR# TEXT MESSAGE(S)
DESCRIPTION OF ERROR
66
Lat cpld illegal xsit mode
An error has occurred in the mode logic.
70
GS tracked w/ GS track req
An error has occurred in the mode logic.
71
GS tracked w/ alt capture req
An error has occurred in the mode logic.
72
Alt hold w/ alt capture req
An error has occurred in the mode logic.
73
Vert cpld illegal xsit mode
An error has occurred in the mode logic.
74
Vert armed #1 illegal xsit mode
An error has occurred in the mode logic.
75
GS armed w/ GS arm req
An error has occurred in the mode logic.
76
Vert armed #2 illegal xsit mode
An error has occurred in the mode logic.
80
Roll illegal xsit mode
An error has occurred in the mode logic.
81
Pitch illegal xsit mode
An error has occurred in the mode logic.
82
Trim illegal xsit mode
An error has occurred in the mode logic.
83
Alt calc illegal xsit mode
An error has occurred in the mode logic.
90
Lat armed invalid
The roll arm mode has been deactivated due to invalid inputs that prevent
proper algorithm calculation. If GPS is the selected arm mode, loss of NAV
valid for 30 seconds or HDG valid for 5 seconds will cancel the roll arm mode.
If LOC is the selected arm mode, loss of NAV valid for 30 seconds or HDG valid
for 5 seconds will cancel the roll arm mode. If VOR is the selected arm mode,
loss of NAV valid for 30 seconds will cancel the roll arm mode.
Revision 2, Dec/2002
CS:15574F02.IDU
BENDIX/KING
KAP 140
POSSIBLE FAILED UNIT(S)
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140
KC 140, Nav Sensor, Hdg Sensor, harness wiring