ERR# TEXT MESSAGE(S)
DESCRIPTION OF ERROR
251
Acc HP has long time constant
Preflight test failed due to the time constant of the high passed acceleration
being too long in the flight computer. This error code is not present in software
flavors --0103, --0104, and --0105. Pitch Axis operation will be disallowed.
252
Norm accel self--test fail
Preflight test failed due to improper response of the accelerometer during
self test. This indicates a probable failure in the accelerometer or the associated
circuitry of the flight computer. This error code is not present in software
flavors --0103, --0104, and --0105. Pitch Axis operation will be disallowed.
Revision 2, Dec/2002
CS:15574F02.IDU
BENDIX/KING
KAP 140
POSSIBLE FAILED UNIT(S)
KC 140
KC 140
Page 5--16