ITEM
GS Valid
Roll Servo Command
Revision 2, Dec/2002
CS:15574F02
BENDIX/KING
KAP 140
DESCRIPTION
Low--level analog validity signal supplied from the
VOR/ILS receiver. Amplitude is based on strength of
radio signal. The GS deviation signal is considered
valid when this output is above 180mV. Input range
is ± 402 mV. Resolution of display value is 0.78mV
per bit. Validity based on internal Analog Valid.
Roll Servo command output signal from FCC looped
back internally for verification during preflight test.
Input range is ± 2.5V. Resolution of display value is
4.9mV per bit. Validity based on internal Analog
Valid.