Honeywell BENDIX/KING KAP 140 Maintenance Manual page 92

Flight control system
Hide thumbs Also See for BENDIX/KING KAP 140:
Table of Contents

Advertisement

5.3 ERROR CODE CATEGORIES
The following lists the general categories in which the KC 140 errors are grouped. It includes a
category name, a description of the category, and the range of error code numbers contained in that
category.
CATEGORY
Exception Vectors
Frame Overrun
Installation
CPU/Powerup
Watchdog
Preflight test
Mode Logic
HW Monitors
Mode Algorithms
RS 232
Altitude errors
Development
Revision 2, Dec/2002
CS:15574F02.IDU
BENDIX/KING
KAP 140
ERROR
DESCRIPTION
RANGE
1
Related to unintended interrupts (exceptions) detected
by the common kernel interrupt service routine (generic
interrupt handler which is used in all KC 140 processors)
2
Processing exceeding allowed time.
5--7
Related to configuration module setup.
10--16
Related to Powerup tests or CPU hardware.
20
Watchdog timeout.
25--54;
Related to failures during preflight test.
240--252
NOTE: If the AP DISC Switch is active (pressed) dur-
ing pre- -flight test, the KC 140 may not pass pre- -
flight test.
55--105,
Related to failures in the mode logic.
110--113
Hardware monitor detected failures.
150--163
Failure in mode algorithm calculation.
175--177
Related to failures in the remote terminal interface.
190--192
Related to altimeter or pressure transducer failures.
200--226
Reserved for failures in development.
Page 5--2