Maintenance; Storage/Winterization; Storing Pump For Winterization; Shaft Seal Change Instructions - Black & Decker BDXBTAGVAR Instruction Manual

Variable speed pump
Table of Contents

Advertisement

Available languages

Available languages

Page 12
ENGLISH

4. Maintenance

This pump requires little or no service other than reasonable care and periodic cleaning of the strainer
basket. DO NOT strike basket to clean. When cleaning the basket inspect the lid O-ring for damage and replace if
necessary.
Pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
Keep motor clean. Ensure motor air vents are free from obstruction to avoid damage. Do NOT use water to
hose off motor.
The mechanical seal may become worn or loose over the course of time, depending on the running time and water
quality. If water continually leaks out, a new mechanical seal should be fitted. After long periods of no
operation (seasonal storage, etc., the pump must be checked for ease of rotation while it is switched off.
Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine seal assembly kit.
Detailed instructions for removing and replacing the mechanical seal begin on page 12. See "6. Shaft Seal
Change Instructions" in this manual.

5. Storage/Winterization

NOTICE: The pump must be protected when freezing temperatures are expected. Allowing the pump to freeze
will cause severe damage and void the warranty.
WARNING: To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining
pump. Failure to disconnect power may result in serious personal injury or death.
Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see
instructions below. Gravity drain system as far as possible.
Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap pump
with plastic film or bags.

5.1 Storing Pump For Winterization

1. Drain water level below all inlets to the pool.
2. Remove drain plugs and strainer cover from strainer housing. (See "Parts Diagram" in section 8.0 of this manual
for pump component locations.)
3. Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping.
4. Once the pump is fully drained of water, re-install the strainer cover and drain plugs. Store pump in a dry area.

6. Shaft Seal Change Instructions

The National Electrical Code requires either a three (3) foot maximum twist-lock cord set with a GFCI
protected receptacle or hard wire (conduit) connection for swimming pool pump installation. When
servicing electrical equipment, basic safety precautions should always be observed including the following.
Failure to follow instructions may result in injury.
WARNING:
1. To reduce risk of injury, do not permit children to use this product.
2. Disconnect all electrical power service to pump before beginning shaft seal replacement.
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ AND FOLLOW ALL INSTRUCTIONS