3.3 Plumbing

When connecting pipework to pump with threaded ports, it is recommended that thread seal tape be used.
Hard-plumbed pipes must have proper solvent-weld connections. Flexible hose connections must be tightened
properly. If the suction line is not sealed correctly, the pump will not prime properly and will pump small volumes of
water or none at all.
Piping - Flexible Hose, PVC, or Reinforced Hose are all acceptable piping methods.
Before starting the pump for the first time, remove the clear lid. (Turn lid ring counter-clockwise to remove.) Fill
strainer tank with water until it is level with the suction inlet. Replace lid with locking ring. Hand-tighten the lid to make
an air-tight seal. DO NOT use any tools to tighten the lid.
To avoid pump strain, support suction and outlet independently. Place supports near pump. To avoid strain left by a
gap at last connection, start all piping at pump and run pipe AWAY from pump.
For pump outlet use 1-1/2" PVC pipe or reinforced hose. For pump suction on ALL models, use 1-1/2"
reinforced hose. Increase size if a long run is needed. For pipe larger than port, use reducing fitting in strainer port.
NEVER use suction pipe SMALLER than pump suction connections. Suction pipe inlet must be lower than pump inlet
port.
Use the fewest number of fittings as possible. Each additional fitting has the effect of moving the equipment farther
away from the water.

3.4 Electrical

• Install all equipment in accordance with the National Electrical code and all applicable local codes and ordinances.
• A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. The Variable Speed Pump must be installed by
WARNING
a licensed or certified electrician or a qualified service professional in accordance with the National Electrical
Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which
could result in death or serious injury to users, installers, or others due to electrical shock, and may also cause
damage to property.
Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so
could result in death or serious injury to service people, pool users, or others due to electric shock
and/or property damage.
Read all servicing instructions before working on the pump.
WARNING: Ground and bond pump before connecting to electrical power supply. Failure to ground
and bond pump can cause serious or fatal electrical shock hazard. Do NOT ground to a gas supply line. To
avoid dangerous or fatal electrical shock, turn OFF power to pump before working on electrical connections.
Fire Hazard - match supply voltage to pump nameplate voltage. Insure that the electrical supply available agrees
with the pump's voltage, phase, and cycle, and that the wire size is adequate for the amps rating and distance
from the power source. Use copper conductors only.