Honeywell JetWave MCS-8562 Installation And Maintenance Manual page 77

Table of Contents

Advertisement

SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
Cable
Conductor Type
A429
Twisted pair, stranded
RS-422
Twisted pair, shielded
Discrete
Twisted pair, shielded, KANDU
Single conductor, shielded, grounds
When installing the JetWave™ MCS-8562 Terminal, follow the cabling requirements listed below:
-
Ethernet LAN/WAN cables must meet flammability and TIA/EIA568-A CAT 5E requirements.
-
When routing JetWave™ MCS-8562 Terminal signals, avoid long wiring runs adjacent with other signals
that could increase the risk of Electro-Magnetic Coupling.
-
Carlisle IT (ECS) 422404 or NF24Q100-01 is recommended for Quadrax connections.
-
Twisted shielded pairs must meet ARINC 791 wiring requirements or equivalent.
Refer to Figure 3-12 for wire size recommendations.
Refer to Figure 3-6 for the Modman (PN 90400012-0001) outline and installation drawing.
Refer to Figure 3-7 for the Modman (PN 90400012-0002) outline and installation drawing.
Refer to Figure 3-8 for the APM (PN 90401121) outline and installation drawing.
Refer to Figure 3-9 for the KANDU (PN 90404518) outline and installation drawing.
Refer to Figure 3-10 for the BUC-HPA (PN 90003227-003), conduction-cooled 1 (maximum operating
temperature of 185°F (85°C)), outline and installation drawing.
Refer to Figure 3-11 for the FMA (PN 90002609-001) outline and installation drawing.
Refer to Figure 3-12 for the JetWave™ MCS-8562 Terminal - FMA (90410870) system interconnect diagram.
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
JetWave™ MCS-8562 Terminal
Table 3-8. Cabling Requirements (Cont)
23-15-84
Single
Multiple
Minimum Conductor
Point
Point
Coverage by Shield
-
Yes
95%
-
Yes
100%
-
Yes
100%
Page 3-25
11 Nov 2020