(b)
(c)
(d)
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
JetWave™ MCS-8562 Terminal
Remove the protective covers from the BUC-HPA J2 and KANDU J3 receptacles.
Visually examine the connectors and make sure that the pins are straight and
undamaged.
1
Clean the connectors with the contact cleaner and connect the cable
assembly for fuselage mount from the KANDU J3 receptacle to the
BUC-HPA J2 receptacle.
2
Make sure that the over braid of the cable assembly is terminated to
connectors at both the BUC-HPA and KANDU ends.
Remove the protective covers from the BUC-HPA J5 and BUC-HPA J6 receptacles.
Visually examine the connector ends and ensure there is no debris in central
connector cavity.
1
Clean the connectors with the contact cleaner before connecting.
2
Make sure that the TX-IF coax cable is banded blue and RX-IF coax cable
is banded green at connector ends.
3
Make sure that the over braid of the cable assembly is terminated to
connectors at both the BUC-HPA and bulkhead interface feed through
ends.
4
The over braid can be terminated to the connector shield/housing or
directly to the housing.
Make sure that all the cable assembly routing are firmly held with wire clamps in
accordance with the airframe specific wiring diagram and there are no obstruction
to the free movement of the FMA.