SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
Consult the airframe manufacturer for the correct torque values.
I.
FMA Installation Procedure
Following installation activities are detailed in subsequent sections:
-
Installation of the FMA.
-
Connecting the waveguide, RF coax interface to the FMA.
-
Installation of BUC-HPA and bonding straps.
-
Installation of waveguide and coax between FMA and BUC-HPA.
-
Connecting Bulkhead Interface, BUC-HPA power and control interfaces.
(1)
Installation of the FMA Assembly
(a)
(b)
(c)
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
JetWave™ MCS-8562 Terminal
Align the FMA assembly above adapter plate with an aircraft service hoist. Attach
hoist to the FMA lifting fixture at two locations on each side of fixture. Refer to
Figure 3-3.
Figure 3-3. FMA Assembly
Put the FMA onto the FMA mounting holes with alignment pins and make sure
that the waveguide flange is pointed to the rear of the AIM or LAIM. Make sure
that the pigtails do not interfere to avoid damage.
Remove the FMA lifting fixture by removing the mounting hardware. Store the
lifting fixture and mounting hardware for future use if the FMA should need to be
removed from the Aircraft. Refer to Figure 3-4.
NOTE:
Honeywell cannot accept the FMA lifting fixture for reuse.
23-15-84
Page 3-19
11 Nov 2020