Wiring Diagram - Makita XRU09 Repair Manual

Hide thumbs Also See for XRU09:
Table of Contents

Advertisement

Fig. 5-2
Note: Be careful not to pinch Corrugated tube of
Power supply cord unit (short) with Strain relief .
Corrugated tube
with Power supply
Strain relief
cord unit (short)
Set the connector on blue lead
wires and black lead wires
to the connector for
Switch unit as drawn.
The Lead wires for Sub controller have to be put
so that the end of Heat shrink tube protrudes
from the border line of Rib A.
Set the connector of Sub controller and the connector on the one of
Power supply cord unit (short) as drawn.
Wiring in Grip set
First, set lead wires of
Switch unit to Grip set.
Heat shrink tube
Do not put the sag of Lead wires on the connectors.
Lead wires of
Power supply cord unit
(short) to Sub controller
Do not put the sag of any Lead wires
on Connectors.
Put Lead wires with tape between
Rib C and Rib B.
Sub controller
Rib C
Rib A
Sub controller
P 16/ 19
Switch unit
Rib B

Advertisement

Table of Contents
loading

Table of Contents