Sony DMX-R100 Operating Instructions Manual page 39

Sony digital audio mixer dmx-r100 operating instructions
Hide thumbs Also See for DMX-R100:
Table of Contents

Advertisement

WRITE buttons on the channel strips: Whenever
you press the WRITE button, all of the controls that
can be dynamically automated in the channel are
READY'ed (i.e. are in READY status).
Notes
• The READY SETUP is automatically switched off
when the timecode is run at PLAY speed.
• When the READY SETUP button is set to ON, the
faders, controls and buttons, do not control the
sound.
5 OPTION button
This button is effective when the READY SETUP
button is light yellow. If you touch this button, the pull
down menu opens and you can select the items to be
READY'ed. When you select WRITE HOLD on the
pull down menu, HOLD is displayed on the button.
• ALL EQ: Sets the faders/equalizers of all channels to
READY.
• ALL DYNA: Sets dynamics of all channels to
READY.
• ALL AUX KNOB: Sets the AUX SEND controls of
all channels to READY.
• ALL AUX BUTTON: Sets the AUX SEND buttons
of all channels to READY.
• ALL CUT: Sets the cut setting of all channels to
READY.
• ALL ASSIGN: Sets the ASSIGN buttons of all
channels to READY.
• ALL PAN: Sets the pan setting of all channels to
READY.
• ALL FADER: Sets the faders of all channels to
READY.
• ALL CANCEL: Sets all READY to SAFE modes.
• WRITE HOLD: Whenever you select this item,
WRITE HOLD mode is switched on and off. When
WRITE HOLD is selected, HOLD is displayed on
the OPTION button. In this mode, items subject to
automation in WRITE mode will not automatically
be set to READY status when the timecode stops.
6 Automation status, sampling frequency,
timecode, mode and error displays
A Automation status display
B Sampling frequency, timecode,
mode, and error display
A Automation status display
Displays the automation status mode.
• READY: Execution of automation is always possible
if the timecode advances at the PLAY speed.
• RUN: Storing/recalling of automation is possible.
• STBY: Automation data cannot be stored due to the
presence of timecode before cue, before the punch in
or after the punch out. However, you can recall
automation.
• OFF: Automation is set to OFF mode. You can
operate all of the buttons and controls manually, but
cannot store/recall automation data.
B Sampling frequency, timecode, mode, and error
display
Displays the sampling frequency and any error
indication. The timecode display is from the internal
timecode reader.
• When an error occurs on the word PLL (or video
PLL), the sampling frequency display turns red.
• When the timecode does not advance correctly, "TC
ERR" is displayed.
• When the format of the entered timecode is different
from the format setting of the unit, the timecode
mode is display in red.
7 RETURN button
Touch this button to return to the previous window
(from which the current window is displayed).
39
Chapter 3 Menu

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents