Honeywell BC-200 Operation, Installation & Programming Manual page 126

Table of Contents

Advertisement

Appendix
9.7.2.3
P
RINTER
Event(max 18 char)
--------------------------------------------------------------------------------
Event Format:
:ALARM
:RESET
:ALARM CLEARED
:PREALARM
:PREALARM CLEARED
:FAULT F05
:FAULT CLEARED
:ACKD ISOL
:DE-ISOLATE
:ACTIVE
:ACKD ISOL FAULT
System Fault Format:
:SYSTEM
:FAULT
:FAULT CLEARED
:SYSTEM
:FAULT
:FAULT
:FAULT
:FAULT CLEARED
:FAULT CLEARED
:FAULT
:FAULT
:FAULT CLEARED
:FAULT CLEARED
:FAULT CLEARED
:FAULT
:FAULT CLEARED
:SYSTEM
:SYSTEM
:FAULT
:FAULT CLEARED
:FAULT
:FAULT CLEARED
Field start positions in output string:
Event
First character in each event is a colon ':' followed by max 18 characters for a description
Zone
Zone number is max 4 characters long and starts at position 21
Point
Point address is max 13 characters long and starts at position 26
Label
Label is max 28 characters long and starts at position 40
Date
Date is max 5 characters long and starts at position 69
Time
Time is max 5 characters long and starts at position 75
There is a semicolon ';' at the end of each line (position 80) followed by a carriage return (ASCII characters 13)
and a line feed (ASCII characters 10)
BC-200 Manual – P/N DOC-01-013
O
F
UTPUT
ORMAT
Zone
Point
Z002 1.1.Z2
ROOM 75 ON SECOND FLOOR
Z002 1.1.Z2
ROOM 75 ON SECOND FLOOR
Z002 1.1.Z2
ROOM 75 ON SECOND FLOOR
Z999 L4D99
ROOM 15 ON THIRD FLOOR
Z999 L4D99
ROOM 15 ON THIRD FLOOR
Z000 L1M7
MONITOR MODULE
Z000 L1M7
MONITOR MODULE
Z000 L1M1
PUMP RUN
Z000 L1M1
PUMP RUN
Z000 0.4.O2
WARNING SYSTEM OUTPUT
Z000 L2D99
KITCHEN IN BUILDING E
Z000
SYSTEM POWER UP
Z000 0.2.I6
BATTERY FAULT
Z000 0.2.I6
BATTERY FAULT
Z000
SYSTEM NORMAL
Z000 0.10.2
PORTA FLT
Z000 NODE100.
NODE DOWN
Z000 0.10.3
PORTB FLT
Z000 0.10.3
PORTB UP
Z000 NODE100.
NODE UP
Z000 N100.0.10.2
PORTA FLT
Z000 N100.0.10.3
PORTB FLT
Z000 N100.0.10.2
PORTA UP
Z000 N100.0.10.3
PORTB UP
Z000 0.10.2
PORTA UP
Z000 0.2.I3
RING POWER SHORT
Z000 0.2.I3
RING POWER SHORT
Z000 0.6.O5
WARN SYS ISOLATED
Z000 0.6.O5
WARN SYS DE-ISOL
Z000 NODE100.
NODE DOWN
Z000 NODE100.
NODE UP
Z000 N100.0.10.4
PROG MODE ACTIVATED
Z000 N100.0.10.4
PROG MODE ENDED
Label(max 28 characters)
Date
Time
03/03 10:07;
03/03 10:08;
03/03 10:08;
03/03 10:10;
03/03 10:10;
03/03 10:12;
03/03 10:13;
03/03 10:14;
03/03 10:17;
07/03 14:39;
07/03 14:39;
03/03 11:33;
03/03 11:33;
03/03 11:33;
03/03 11:33;
03/03 11:34;
03/03 11:46;
03/03 11:46;
03/03 11:47;
03/03 11:47;
03/03 11:47;
03/03 11:47;
03/03 11:47;
03/03 11:47;
03/03 11:49;
03/03 11:51;
03/03 11:51;
03/03 10:42;
03/03 10:48;
03/03 10:48;
03/03 10:49;
03/03 10:50;
03/03 10:50;
126