Honeywell NOTIFIER SFP-5UD Series Manual page 116

Fire alarm control panels
Hide thumbs Also See for NOTIFIER SFP-5UD Series:
Table of Contents

Advertisement

Ademco Contact ID Format Event Code Descriptions
EVENT
350 Communication
351 Telco 1 fault
352 Telco 2 fault
353 Long range radio xmitter fault
354 Fail to communicate
355 Loss of radio supervision
356 Loss of central polling
Protection Loop Troubles - 370
370 Protection loop
371 Protection loop open
372 Protection loop short
373 Fire trouble
Sensor Troubles - 380
380 Sensor trouble
381 Loss of supervision - RF
382 Loss of supervision - RPM
383 Sensor tamper
384 RF transmitter low battery
Open/Close - 400
400 Open/Close
401 Open/Close by user
402 Group Open/Close
403 Automatic Open/Close
404 Late Open/Close
405 Deferred Open/Close
406 Cancel
407 Remote arm/disarm
408 Quick arm
409 Keyswitch Open/Close
Remote Access - 410
411 Callback request made
412 Success - download/access
413 Unsuccessful access
414 System shutdown
415 Dialer shutdown
416 Success - upload/access
Access Control - 420
421 Access denied
422 Access report by user
System Disables - 500 and 510
116
MESSAGE
TROUBLE - Communication Trouble
TROUBLE - Phone Line #1
TROUBLE - Phone Line #2
TROUBLE - Radio Transmitter
TROUBLE - Fail to Communicate
TROUBLE - Radio Supervision
TROUBLE - Central Radio Polling
TROUBLE - Protection Loop - #
TROUBLE - Protection Loop Open - #
TROUBLE - Protection Loop Short - #
TROUBLE - Fire Loop - #
TROUBLE - Sensor Trouble - #
TROUBLE - RF Sensor Supervision - #
TROUBLE - RPM Sensor Supervision - #
TROUBLE- Sensor Tamper - #
TROUBLE - RF Sensor Batt. - #
OPENING
OPENING - User #
OPENING - Group User #
OPENING - Automatic
OPENING - Late
Opening not used
OPENING - Cancel
OPENING - Remote
Opening not applicable
OPENING - Keyswitch
REMOTE - Callback Requested
REMOTE - Successful Access
REMOTE - Unsuccessful Access
REMOTE - System Shutdown
REMOTE - Dialer Shutdown
REMOTE - Successful Access
ACCESS - Access Denied - User #
ACCESS - Access Gained - User #
SFP-5UD & SFP-10UD Series Manual— P/N 52879:C6 6/12/2018
Ademco Contact ID Typical Printout
CLOSING
CLOSING - User #
CLOSING - Group User #
CLOSING - Automatic
CLOSING - Late
Closing not used
Closing not used
CLOSING - Remote
CLOSING - Quick Arm
CLOSING - Keyswitch
(restore not applicable)
(restore not applicable)
(restore not applicable)
(restore not applicable)
(restore not used)
(restore not used)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Notifier sfp-10ud seriesNotifier sfp-5udNotifier sfp-5udeNotifier sfp-5udcNotifier sfp-10udNotifier sfp-10ude ... Show all

Table of Contents