5-8. Power Consumption Measurement

5-8-1. Test equipment confi guration
Direct current stabilized power source
5-8-2. Measurement items and specifi cations
Item

Run mode

Sleep mode
Main Dummy load
OFF
Laser Scanner movement
Linear Imager movement
2D Module movement
5-8-3. Run mode
No
Operation
Set the supply voltage to
4.0V.
Select [Run mode
current] in the test
program.
1
DC Ammeter
Supply voltage
4.0V
200 mA or lower
4.0V
65 mA or lower
4.0V
70-100 mA
4.0V
1 mA or lower
4.0V
150 mA or lower
4.0V
150 mA or lower
4.0V
360 mA or lower
Display
Backlight is turned off.
— 60 —
DT-X100
Tape down the battery
cover sensor button.
Battery terminal
Current value
Check that the current value is as follows.
- "200 mA" or lower
Within spec: Press the "1" key.
Out of spec: Press the "0" key.
Pressing "1" or "0" returns you to the
Menu screen.