Ren Connected To Line; Ringing Supply; Ringing Cadence; Ringing Duration - GE JungleMUX 86445-31 Technical Practice And Installation Manual

Sonet multiplexer
Table of Contents

Advertisement

REN connected to line

The maximum Ringer Equivalent Number for each line (typically equals to the
max number of telephones paralleled) is 2 (two).

Ringing Supply

The Ringing Supply parameters for the 86445-32 2W FXS unit are:

Ringing Cadence

PLAR mode:
LS or GS mode:

Ringing Duration

In PLAR mode:
LS or GS mode:

Ring Trip

Signaling States

The Signaling States for FXS mode and PLAR mode are given in the following
tables:
Copyright  GE Multilin Inc. 2002
70 Vac, 20 Hz, sinusoidal balanced ringing
2 sec ON + 4 sec OFF
Follows cadence received from far-end
Configurable to 10 sec, 20 sec, 60 sec or Indefinite.
Unlimited (driven by the incoming signaling)
<200 msec
342-86400-445PS
Issue 4.0
October 2006