Note: When in Line Loopback test mode, the unit's Transmit and
Receive Levels (VF Setup window) should be set to 0 dBm.
Note: This field must be set to 'None' when not being used for test
or maintenance purposes.
XMT Signalling
Allows the user to set a specific signaling condition that will be sent
to the far-end unit and is used for test/maintenance purposes only.
The signaling options available depend on the Signalling Type
selected (see Signalling Setup window).
Note: This field must be set to '-' when not being used for test or
maintenance purposes.
Note: When testing from near end to far end, the far-end unit
Receive Signalling should be configured to '-'.
Note: The unit's yellow (BUSY) LED illuminates only if an OFF-
HOOK condition is initiated from an external source (i.e. signaling
test set or telephone).
RCV Signalling
Allows the user to set a specific signaling condition that will be sent
to the local drop equipment and is used for test/maintenance
purposes only.
Type selected (see Signalling Setup window).
Note: This field must be set to '-' when not being used for test or
maintenance purposes.
Signalling Monitor
XMT Signalling
Shows current signaling status sent towards the far-end unit.
Receive Signalling
Shows current signaling status received from the far-end unit
(unless overridden by the locally forced RCV Signalling test
condition in which case the forced condition is displayed).