Ringing Supply; Ringing Cadence; Ringing Duration; Ring Trip - GE JungleMUX 86445-31 Technical Practice And Installation Manual

Sonet multiplexer
Table of Contents

Advertisement

Ringing Supply

The Ringing Supply parameters for the 86445-31 2W FXS unit are:

Ringing Cadence

PLAR mode (& micro code ≥2.05):
PLAR mode (& micro code <2.05):
LS or GS mode:

Ringing Duration

In PLAR mode (& micro code ≥2.05):
In PLAR mode (& micro code <2.05):
LS or GS mode:

Ring Trip

Trip of ringing during ringing or silent interval: <250msec

Signaling States

The Signaling States for FXS mode and PLAR mode are given in the following
tables:
Copyright  GE Multilin Inc. 2002
Frequency: 20 Hz nominal
Output Voltage: 86V 0 to peak
Output Power: 5W
Wave form: Square wave

Table 11: Ringing Supply Parameters

342-86400-445PS
Issue 4.0
October 2006
Page 42
Configurable to North American,
European or Steady
Steady
Follows cadence received from
far-end
Configurable to 10 sec, 20 sec,
60 sec or Indefinite
Unlimited (driven by the incoming
signaling)
Unlimited (driven by the incoming
signaling)