1.5 INSTALLATION

The following section provides information for installing an 86445-31 FXS unit.
The unit is shipped from the factory configured as per the Node Assignment
Drawing for the purchased system. All spare units or loose units are shipped
with factory default settings in memory.
The 86445-31 2W FXS unit has ESDS components and therefore standard
static protection precautions should be observed when handling, packing

Pre-installation

Visually check the unit for damage. Ensure that screws are firmly tightened and
in place. Keep the shipping containers and packing materials for future use. If a
unit is damaged, file a claim with the shipping agent or the local GE Multilin
representative.
Set the unit line impedance, network build-out capacitance (NBOC), and current
limiting as desired. Refer to the strapping options in Table 1. Factory default
settings are 600Ω for line impedance, 0nF for NBOC, and 20mA for current
limiting.
Function
Jumper
NBOC 1
P4-19 to P4-20
NBOC 2
P4-17 to P4-18
R=900Ω
P4-13 to P4-14
R=600Ω
P4-15 to P4-16
Z=R
P4-11 to P4-12
Z=R+Xc
P4-9 to P4-10
P4-1 to P4-2
Current
P4-3 to P4-4
Limiting
P4-5 to P4-6
P4-7 to P4-8

Table 1: 86445-31 FXS Unit Strapping Options

Copyright  GE Multilin Inc. 2002
CAUTION
or shipping the unit.
Adds 22 nF to network build-out capacitance
Adds 47 nF to network build-out capacitance
Line impedance at 2W VF port
Line impedance at 2W VF port
Sets impedance to resistive only
Adds capacitive reactance to impedance (2.15 µF in
series)
Current limiting is 20 mA
Current limiting is 30 mA
Current limiting is 40 mA
Current limiting is 50 mA
342-86400-445PS
Issue 4.0
October 2006
Page 22