 The termination PCB (6580500126) where the scanner and sensor IO will be
terminated.
 The EDAQ based frame controller assembly (6580801565).
 Programmed MSS computer (6580801828)
 The programmed MSS computer (6580801828).
 Between two and six sensor EDAQ boards (6581500030).
 A time delay relay (6541310061).
 Two 24V power supplies (6541002775).
 An AC motor controller (6541900038)
Termination board 6580500126
The termination PCB (6580500126) is the termination location for the majority of
the scanner and sensor field IO into the Q4610-00 cabinet. One of the important
functions of this board is to receive the field IO, in some cases condition the signals,
and provide the interface to the EDAQ based frame controller, motor controller
and sensor EDAQs
Figure 13 Termination Board
The termination PCB (6580500126) includes the functionality of several cards that
were
once
provided
on
individual
PCBs
on
some
older
PMPs.
Namely,management of the ash radiation interlocking, voltage to frequency
conversion for caliper and motor logic functionality are on board the termination
PCB in the 4610-00.