Bump Test - Honeywell BW Flex Series User Manual

Portable multiple gas detector
Table of Contents

Advertisement

Bump Test

The detector can be tested in four ways:
Via the detector's menu.
l
Via the Safety Suite Device Configurator (SSDC) software on a computer.
l
Via the Device Configurator (DC) app on a mobile Detector.
l
Via the IntelliDoX Docking Module. For further reference see the IntelliDoX User Manual.
l
Move to a normal atmosphere (20.9% v/v O
l
Honeywell recommends bump testing the sensors before each day's use to confirm their
l
ability to respond to gas by exposing the Detector to a gas concentration that exceeds the
alarm setpoints. Manually verify that the audible and visual alarms activate.
Details for Bump Test and maintenance:
Recommendations for initial checking of the equipment on a routine basis including the
l
maximum time interval between calibrations.
The combustible sensor is factory calibrated to 50% LEL methane. If monitoring a different
l
combustible gas in the % LEL range, calibrate the sensor using the appropriate gas.
BW Flex Series
CAUTION
) that is free of hazardous gas.
2