Honeywell BW Icon, BW Icon + - Gas Detector Quick Reference Guide

Honeywell BW Icon, BW Icon + - Gas Detector Quick Reference Guide

Also See for BW Icon:

Advertisement

Honeywell BW Icon, BW Icon + - Gas Detector Quick Reference Guide

Introduction

The Honeywell BW™ Icon & BW™ Icon+ gas detectors warns of hazardous gas at levels above user-defined alarm setpoints.

The detector can monitor up to four gases at a time.

Refer to the Honeywell BW™ Icon User Manual for the full list of gases.

What's in the Box

  • Honeywell BW™ Icon gas detector
  • Battery (factory-installed)
  • USB charger
  • 1 Calibration cap
  • Quick Reference Guide
  • Tubing
  • 1 Klick Fast stud

User Interface

Alarm One — Shows when alarm one is breached and gas highlighted next to sensor
Alarm Two — Shows when alarm two is breached. Alarm two will over write any alarm one status
Time Weighted Average — Settable in Safety Suite DC for each toxic sensor
Short Term Exposure Limit — Settable in Safety Suite DC for each toxic sensor
Bump — Shows when bump is due and you can configure to have a count down.
Calibration — Shows when bump is due and you can configure to have a count down.
Battery status — Shows battery status and when on charge will show charging status
Bluetooth — All devices have Bluetooth – double click to enter menu for search mode

Overview

Overview

  1. LED Alarm
  2. IntelliFlash
  3. Display
  4. Button
  5. Beeper
  6. Sensor
  7. Clip
  8. Battery
  9. Charging Port

Common device's operations

Common Operations

Power On 4-second hold
Power Off 4-second hold
Enter and exit Menus Double-press
Select Next Single-press
Initiate Selected 3-second Hold
Acknowledge latched alarm 1-second hold

Bump Test and Calibration via a Mobile Device

  1. Turn On the BW Icon. Place the cap over the detector, and then press down on both tabs to snap it into place.
    Bump Test and Calibration via a Mobile Device - Step 1
  2. Attach the hose.
    Bump Test and Calibration via a Mobile Device - Step 2
  3. In your mobile device, open the Device Configurator app .

  4. In your BW Icon:
    • Double press to enter the menu
    • Single press until the BLE icon is displayed
    • Hold press 3 secs to initiate the pairing mode.
      Bump Test and Calibration via a Mobile Device - Step 3
  5. In the Device list screen from the Device Configurator app, select the BW Icon Serial Number to start pairing.
    The upper LED and the BLE icon will light in green after pairing succeed.
  6. In your Mobile device:
    • Tap on the Menu button .
    • Select Remote Calibration or Bump .
    • Follow on-screen instructions.
  7. The process is complete when the results are displayed on your mobile device. You can now remove the cap by pulling on the tabs.

    Read the User Manual for complete information on the BW Icon operation.

Safety Certifications

Ex (IECEx & ATEX):
IEC60079-0, 2017
IEC60079-11, 2011-7 Edition 6.0
IEC61010-1
II 1G Ex ia I/IIC T4 Ga ( -40°C ≤ Tamb ≤ 60°C )

IP: IEC60529, IP66, IP68

CE (EMC): EN50270,2015 Type 2

CE LVD: EN60950, EN61010

CE (BLE):
EN300 328
EN301 489-1
EN301 489-17
R&TTE Directive 2014/53/EU EN62479, 2010

CE (ROHS): EN50581, 2012

FCC & IC:
47CFR Part 15
ANSI C63

  • The detector is a personal safety device. It is your responsibility to respond properly to the alarm.
  • For safety reasons, this equipment must be operated and serviced by qualified personnel only.
  • The lithium battery in this product presents a risk of fire, explosion, and chemical burn if misused. Do not disassemble, incinerate, or heat above 212°F (100°C). Batteries exposed to heat at 266°F (130°C) for 10 minutes can cause fire and explosion. Batteries must only be charged in a safe area free of hazardous gas.
  • Deactivating the detector by removing the battery pack may cause improper operation and harm the detector.
  • Use only Honeywell approved battery chargers such as the vehicle Charger.
  • Do not use the apparatus if it is damaged. Inspect the apparatus before use. Look for cracks and missing parts.

Contact Us

Europe, Middle East, Africa
Life Safety Distribution GmbH
Toll-Free 00800 333 222 44
Middle East +971 4 450 5800
Middle East +971 4 450 5852
(Portable Gas Detection)
gasdetection@honeywell.com

Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
detectgas@honeywell.com

Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700
analytics.ap@honeywell.com

Technical Services
EMEA: HAexpert@honeywell.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com

www.honeywellanalytics.com

© June 1, 2020
M05-4002-000-RevA

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Honeywell BW Icon, BW Icon + - Gas Detector Quick Reference Guide

Advertisement

Need Assistance?

Do you have a question about the BW Icon that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents