Sensor
Measuring Range
CO
0-2000 ppm
H
S
0-200 ppm
2
SO
0-150ppm
2
O
0-30% v/v
2
LEL IR
0-100% LEL CH
4
LEL
0-100% LEL
Sensor
SPAN Count Down
CO
60 sec
H
S
60 sec
2
SO
90 sec
2
O
60 sec
2
LEL IR
60 sec
LEL
60 sec
Sensor
CO
H
S
2
SO
2
O
2
LEL IR/LEL
BW Flex Series
Resolution
1 ppm
1/0.1ppm
0.1ppm
0.1% VOL
1% LEL CH
4
1% LEL
Default SPAN Value
100ppm
25ppm
20ppm
18.0% v/v
50% LEL CH
4
50% LEL
Default Low Alarm
35ppm
200ppm
10.0ppm
15.0ppm
2.0ppm
5.0ppm
19.5% v/v
23.5% v/v
10% LEL
20% LEL
Measuring Unit
3
ppm, mg/m
, µmol/mol
3
ppm, mg/m
, µmol/mol
3
ppm, mg/m
, µmol/mol
%VOL
%LEL, % v/v
%LEL, % v/v
Calibration Flow Rate
500ml/min
500ml/min
500ml/min
500ml/min
500ml/min
500ml/min
Default High Alarm
35ppm
10.0ppm
0.5ppm
N/A
N/A LEL
42
Working Temperature
-40°C to +60°C
-40°C to +60°C
-40°C to +55°C
-40°C to +60°C
-40°C to +60°C
*
-20°C to +60°C
*
Can be operated from -40°C to -20°C
New Sensor Stabilization Time
0.5 hour
0.5 hour
0.5 hour
24 hours
N/A
N/A
Default TWA
Default STEL
50ppm
15.0ppm
1.0ppm
N/A
N/A LEL
User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bw flex-iBw flex4

Table of Contents