DataLogs and Event Logs

DataLogs
The detector records various information to create a report. The detector is capable of storing
45 days of data at 15 sec interval, 8hrs/day.
When the memory is full, the detector replaces the oldest datalogs with the most recent
datalogs.
Event Logs
The detector records a maximum of 50 gas alarm, maintenance events, and error conditions.
The following event types are recorded:
1: Gas high
2: Gas low
3: Gas STEL
4: Gas TWA
5: Gas over range
6: Gas negative
7: Sensor failure
8: Multi alarm
9: Zeroing
10: Spanning
11: Bumping
12: Disabled
BW Flex Series