25 - Access Doors (cont'd)
Access Log Information
The access log contains a reason why the door will not operate. These can be:
Not Grp Match
Reject Grp Set
Illegal Time
The keypad display in the access log also shows user information:
Press the # key to view the reason for rejection:
The line number for MAX or prox readers is in the format, for example 0013:
00 = not required
1 = line number 1
3 = Address number 3.
Access Log Print and Store Option
The Access Doors (MAX Log) is printed on-line and stored in the event memory.
The Access Door Log print displays in the format of the Event Log and allows information to be accessed.
The format is as follows:
HH:MM_XXXXXXXXXX_USR_NNN_UUUUUU_MYY_—_ (39 character display)
HH:MM = time in hour:minutes (5 characters). The date will be printed only at the beginning of every day,
that is midnight.
XXXXXXXXXX = access message (10 character) Valid, Invalid Card, Reject Card
USR = User (3 characters)
NNN = User number to which MAX card is assigned (3 characters)
UUUUUU = User descriptor (6 characters)
M = MAX reader address (1 character)
YY = MAX physical address-M10, M24 etc (3 characters)
- (dash) = unused character slot
__ (underscore) = this represents a space and is not printed or displayed in the access log.
For example: A valid card read at MAX
be:-
13:48 Valid USR 020 Albert M30 –
Line number
30 from the card held by user 020, name Albert, at 13:48 would
3
6-20
Galaxy Dimension Installer Manual
01:00 THU 26 APR
01:00 THU 26 APR
01:00 THU 26 APR
01:00 THU 26 APR
01:00 THU 26 APR
U S E R
U S E R
U S E R
001 Rejct
001 Rejct
001 Rejct
U S E R
U S E R
001 Rejct
001 Rejct
DCM Address
Reader number
1 0 2 1
1 0 2 1
1 0 2 1
1 0 2 1
1 0 2 1
Reject Grp Set
Reject Grp Set
Reject Grp Set
Reject Grp Set
Reject Grp Set
Grp A1
Grp A1
Grp A1
Grp A1
Grp A1