51 - Parameters (cont'd)
25 = Global Copy
The Global Copy parameter changes all zones within the selected range to the function and parameters of the
first zone in the range. On selection of the parameter, a warning message is displayed indicating that the zone
functions will be altered — WARNING!!! ENT=ZONE CHANGES: press the ent key to continue or the
esc key to abort the programming. The address and function of the first zone on the system are displayed:
Copy Start: Use the A or B key to select the first zone in the range to be copied and press the ent key.
The function of this zone will be copied to all subsequent zones in the range;
Copy End: Use the A key to move to the last zone in the range to be copied.
Press the ent key to copy the zone function to the selected range.
26 = Forced
The Forced parameter enables or disables Menu option 14 = FORCED SET. If the parameter is set to 1
(enabled) the user can force the system to set, automatically omitting any omittable zones that are open at the
time of setting. If the parameter is set to 0 (disabled), option 14 = FORCED SET is not available to the user;
the message Option not available is displayed. The parameter defaults to 0 (disabled).
NOTE: It is recommended that Final, Entry and Push-Set zones have the omit attribute disabled.
27 = CCT Debounce
The cct Debounce parameter determines the response time of the zones (how long they must remain open
before registering as changing state). The cct Debounce is programmable within the range 20–1000 millisec-
onds (0.02–1 second); the default is 300 msecs. All entries are rounded up to the nearest 20 msecs.
NOTE: The value programmed in this option is the value allocated to the SYSTEM selection when program-
ming zone response time in option 52.
28 = Online Print
This parameter is used to select the print mode required when connecting a serial printer to the Galaxy panel;
there are two options:
0 = disabled (default): system only prints specific details at the user's request. The printer can be
connected and disconnected at any time as required;
1 = enabled: this option switches the printer to on-line mode and requires that a printer be
continuously connected to the system. Events are printed as and when they occur. The events printed
are controlled by parameter 29 = Online Level.
NOTE: If Online Print is enabled, the event log and other options will not be printed at the user's request.
The parameter must be disabled to permit all other print options to operate.