42 - Codes (cont'd)
2=Modify Level
Each user is assigned an access level which determines the menu options available to the user. The program-
mable level are from 1.0 - 2.5.
3.6 is assigned to the manager.
3.7 is assigned to the engineer — this is fixed and cannot be assigned to user codes.
3.8 is assigned to the remote code. This is fixed and cannot be assigned to the engineer or user codes. The
remote code can only be used via keypads addressed as E.
On selecting this option, enter the level to be assigned to the user and press the ent key to accept the pro-
gramming and return to the previous menu level.
EN50131-1
Level
1
2
2
2
2
2
2
3
3
Duress Code
If the # key is pressed while the Modify Level option is accessed, then the current user code is assigned as a
Duress Code. Entry of a Duress Code at any time activates any output programmed as Duress (refer to
option 53 = OUTPUTS). There is no limit to the number of codes that can be assigned as Duress Codes.
Entry of any valid user code followed by ## is also a duress code (disabled in the UK to comply with
regulations).
Quick Menu
All of the user codes default to the quick menu. This menu is made up of a selection of ten options
(0 – 9) from the full menu options 11 – 68. Access to the quick menu is controlled by the user type. Any user
can be upgraded from the quick menu to the full menu by assigning a
option is accessed. Therefore a user with type 2.5 would have access to the full menu from options 11 – 42.
No code can access both menus.
The engineer can reprogram the options contained in the quick menu (refer to option 59 = QUICK MENU).
NOTE: The master manager code defaults to the full menu.
The engineer can determine the menu option access type (refer to option 68 = MENU ACCESS); this allows
users to access menu options that their code types are not, by default, authorized to access.
Level
1.0†
Guard
Entered into event memory – no other option
2.1†
Cleaner
Can only set the system and change own PIN
2.2†
Caretaker
Can only set and unset the system and change own PIN
2.3
Users
Menu options 11 - 19
2.4
Users
Menu options 11 - 25
2.5
Users
Menu options 11 - 32
3.6‡
Manager
Menu options 11 - 48
3.7‡
Engineer
Menu options 11 - 71
3.8‡
Remote
Menu options 11 - 71
No access to menu functions
The manager, engineer and remote codes (the last three codes on
the system) have fixed types which cannot be reprogrammed.
NOTE: All levels except guard can change their own PIN.
Table 6-6. User Access Levels
Galaxy Dimension Installer Manual
Access Availability
to the user while the Modify Type
6-32