56.1.06 Dial Type
The transmission mode can be selected from two types:
1. Tone (also known as "DTMF Dial") this is much quicker at dialling than the Pulse option.
2. Pulse (also known as "Rotary" or "Loop Disconnect") is universal, however, an increasing number of
exchanges now provide the Tone (DTMF Dial) option.
NOTE: If unsure of the type of exchange that the panel is connected to, leave as Pulse dialling.
56.1.07 Autotest
An engineer test can be automatically transmitted to the Monitoring Station at programmed intervals, in order
to indicate alarm transmission path integrity.
1 = Start Time
The engineer uses this option to enter the time that the first engineer test is transmitted. Subsequent engineer
test transmissions are offset by the value assigned in the Test Interval option.
2 = Intervals
This option determines the period between engineer test transmissions following the Start Time, the program-
mable range is 0 – 99 hours.
NOTES:
1. If the Test Interval is 0 (default) the Autotest is disabled — even if a Start Time has been assigned.
2. To disable Autotest enter 00:00 (default); no transmissions of test signals can be sent at midnight.
3 = Intelligent Test
This option stops the transmission of an automatic engineer test if an alarm signal has already been sent during
the autotest interval.
4 = Group Condition
NOTE: This option is only displayed if the groups have been enabled (refer to option 63 = OPTIONS).
The Group Condition determines the status that each group must satisfy before the Autotest is transmitted.
This can be used to prevent an Autotest from being signalled when groups are set on the system. On selecting
this option press the relevant number keys to toggle the status of the groups and press the ent key to accept
the programming. The available group status conditions are:
S = Set - group must be set to allow autotest transmission;
U = Unset - group must be unset to allow autotest transmission;
– = Set or unset - autotest transmission is independent of the group status.
56 - Communications (cont'd)