Honeywell Galaxy Dimension Series Installer Manual page 177

Hide thumbs Also See for Galaxy Dimension Series:
Table of Contents

Advertisement

Galaxy Dimension Installer Manual
53 - Program Outputs (cont'd)
77 Bell Test
This output activates when Bell Test is selected via menu 32. This causes the bell and strobe output to
activate. This output is normally used to activate a relay to cut power to the bell.
78 Comms Test (Pulse)
This output is used for remote routine inspection, via the downloader software. When a remote inspection is
carried out, this output will activate for 10 seconds in order to trigger the test input of an external comms
device.
79 Door Prop
This output activates when a door is held open for longer than the programmed time and an Open Timeout
occurs (Option 69).
80 Door Force
This output activates when a door is forced open without authorization and an alarm occurs.
81 Listen-in
This output activates after an alarm activation and an audio transmission is in progress.
6-103